In the process of ion chromatography analysis, there are often impurity interferences in the sample. For example, organic matter will contaminate the packing of the ion chromatography column, reducing the separation ability of the column and service life of the column, and impurity ions will interfere with the separation of target ions.
LabGo IC series ion chromatography sample pretreatment column, is developed based on the principle of solid phase extraction, using high-purity materials and utilizing reverse phase adsorption, adhering to the mechanism of ion exchange, it can effectively remove organic matter and impurity ion, which can avoid the contamination of ion chromatography columns by impurities and their impact on separation.
Product Features
*Imported medical-grade raw materials, the products are highly transparent and ultra-pure are highly transparent and ultra-pure;
*Various products and specifications meet the different needs of different customers;
*Simple and fast, has a good impurity removal effect, low ion residue: using high cleanliness filler, ion residue can be as low as ppb level!
*Clean room production in all links of the product, assembly line operation, optical robot quality inspection, full ERP management,
*Wide range of applications: It is suitable for a variety of Fungaltoxin detection experiments. This series of products accepts customer’s personalized customization and function development!
| Sorbent | Description & Application | Form | Spec. | Pcs/pk/bag | Cat.No |
|
Ag |
Ag type strong acidic cation exchange resin
Applications: soil; water; body fluids (plasma/urine, etc.); food; pharmaceuticals.
Ag resin can easily removes chlorides, bromides and iodides from concentrated sample matrices.
Typical applications: Removal of high concentrations of chloride ions in environmental, food samples, etc. Easily removes chlorides, bromides and iodides from concentrated sample matrices.
|
1ml | 300mg/1ml | 100 | ICAG1300 |
| 1ml | 400mg/1ml | 100 | ICAG1400 | ||
| 2.5ml | 750mg/2ml | 100 | ICAG2750 | ||
| 2.5ml | 1000mg/2ml | 100 | ICAG21000 | ||
| 3ml | 1200mg/3ml | 100 | ICAG31200 | ||
|
sorbent
|
100g | 1 | ICAG100 | ||
|
Ba |
Ba Type Strongly Acidic Cation Exchange Resin
Applications: Soil; water; body fluids (plasma/urine, etc.); food; pharmaceuticals.
Typical applications: Removal of high concentrations of sulfate ions in environmental samples, food samples, etc.
|
1ml | 300mg/1ml | 100 | ICBA1300 |
| 1ml | 400mg/1ml | 100 | ICBA1400 | ||
| 2.5ml | 750mg/2ml | 100 | ICBA2750 | ||
| 2.5ml | 1000mg/2ml | 100 | ICBA21000 | ||
| 3ml | 1200mg/3ml | 100 | ICBA31200 | ||
| sorbent | 100g | 1 | ICBA100 | ||
|
C18
|
Reversed phase C18 packing
Applications: soil; water; body fluids (plasma/urine, etc.); food; pharmaceuticals.
Typical applications: Removal of organic matter from environmental samples, food samples, etc.
|
1ml | 400mg/1ml | 100 | ICC181400 |
| 2.5ml | 1000mg/2ml | 100 | ICC1821000 | ||
| 3ml | 1200mg/3ml | 100 | ICC1831200 | ||
| Sorbent | 100g | 1 | ICC18100 | ||
|
H
|
H type strong acidic cation exchange resin
Applications: Soil; water; body fluids (plasma/urine, etc.); food; pharmaceuticals.
Typical applications: Removal of alkaline metal ions such as calcium, transition metal ions and other polyvalent cations and carbonate ions from sample matrix, also used to neutralize the strong alkaline nature of the sample solution.
|
1ml | 400mg/1ml | 100 | ICH1400 |
| 2.5ml | 1000mg/2ml | 100 | ICH21000 | ||
| 3ml | 1200mg/3ml | 100 | ICH31200 | ||
| Sorbent | 100g | 1 | ICH100 | ||
|
Na
|
Na type strong acidic cation exchange resin
Applications: Soil; water; body fluids (plasma/urine, etc.); food; pharmaceuticals.
Typical applications: Removal of alkaline metal ions, transition metal ions from sample matrix.
|
1ml | 400mg/1ml | 100 | ICNA1400 |
| 2.5ml | 1000mg/2ml | 100 | ICNA21000 | ||
| 3ml | 1200mg/3ml | 100 | ICNA31200 | ||
| Sorbent | 100g | 1 | ICNA100 | ||
|
RP
|
Polystyrene/Divinylbenzene polymers
Applications: Soil; water; body fluids (plasma/urine, etc.); food; pharmaceuticals.
Typical applications: Removal of organic compounds especially unsaturated and aromatic compounds.
|
1ml | 400mg/1ml | 100 | ICRP1400 |
| 2.5ml | 1000mg/2ml | 100 | ICRP21000 | ||
| 3ml | 1200mg/3ml | 100 | ICRP31200 | ||
| Sorbent | 100g | 1 | ICRP100 | ||
|
Ag/H |
Ag/H type strong acidic cation exchange resin
Applications: Soil; water; body fluids (plasma/urine, etc.); food; pharmaceuticals.
Typical applications: Functionally equivalent to the use of Ag and H in tandem. |
1ml | 300mg/1ml | 100 | ICAGH10CC |
| 2.5ml | 750mg/2ml | 100 | ICAGH25CC | ||
| 3ml | 1000mg/3ml | 100 | ICAGH30CC | ||
|
Ag/Na
|
Ag/Na type strong acidic cation exchange resin
Applications: Soil; water; body fluids (plasma/urine, etc.); food; pharmaceuticals.
Typical applications: Functionally equivalent to the tandem use of Ag and Na. |
1ml | 300mg/1ml | 100 | ICAGNA10CC |
| 2.5ml | 750mg/2ml | 100 | ICAGNA25CC | ||
| 3ml | 1000mg/3ml | 100 | ICAGNA30CC | ||
|
Ba/H |
Ba/H type strong acidic cation exchange resin
Applications: Soil; water; body fluids (plasma/urine, etc.); food; pharmaceuticals.
Typical applications: Functional equivalent of Ba, H used in series. |
1ml | 300mg/1ml | 100 | ICBAH10CC |
| 2.5ml | 750mg/2ml | 100 | ICBAH25CC | ||
| 3ml | 1000mg/3ml | 100 | ICBAH30CC | ||
|
Ba/Na
|
Ba/Na type strong acidic cation exchange resin
Applications: Soil; water; body fluids (plasma/urine, etc.); food; pharmaceuticals.
Typical applications: Functionally equivalent to the use of Ba and Na in series. |
1ml | 300mg/1ml | 100 | ICBANA10CC |
| 2.5ml | 750mg/2ml | 100 | ICBANA25CC | ||
| 3ml | 1000mg/3ml | 100 | ICBANA30CC | ||
|
Ba/Ag/H
|
Ba/Ag/H type strong acidic cation exchange resin
Applications: Soil; water; body fluids (plasma/urine, etc.); food; pharmaceuticals.
Typical applications: Functionally equivalent to the use of Ba, Ag, H in series. |
1ml | 300mg/1ml | 100 | ICBAAGH10CC |
| 2.5ml | 750mg/2ml | 100 | ICBAAGH20CC | ||
| 3ml | 1000mg/3ml | 100 | ICBAAGH30CC | ||
| Ba/Ag/H | IC-Ba/Ag/H Styrenesulfonate Resin Ionic Columns are ideal for removing high concentrations of alkaline earths and transition metals from sample matrices to neutralize alkaline samples as well as for removing carbonates. The triple composite column can be used in place of three single tandem columns and also offers the advantage of a higher silver capacity. | 50 | IC1225-50 | ||
| Personalized Customization | Customization | Customizing |
Ion Chromatography Sample Pre-treatment Columns with Empty Columns and Frits
| Spec. | Form | Description & Application | Spec. | Pcs/pk/bag | Cat.No |
|
1ml |
Snap Seal |
1ml volume, PP two-piece set (snap seal), two pieces of UHMWPE hydrophobic frit | HF091-25-020 | 100 | IC1 |
|
1ml |
annular seal |
1 ml volume/3 ml inner and outer diameters of column tubes, PP three-piece set (O-ring seal), two pieces of UHMWPE hydrophobic frit | HF090-25-020 | 100 | IC1AA |
|
1ml |
Bayonet Seal |
1ml volume/3ml inner and outer diameters of column tubes, PP two-piece set (bayonet seal), two pieces of UHMWPE hydrophobic frit | HF090-25-020 | 100 | IC1AB |
|
1ml |
Bayonet Seal |
1 ml volume/6 ml inner and outer diameters of column tubing, PP two-piece set (bayonet seal), two pieces of UHMWPE hydrophobic frit | HF130-25-020 | 100 | IC1B |
|
1.5ml |
Snap Seal |
1.5 ml volume/3 ml inner and outer diameters of column tubes, PP two-piece set (snap seal), two pieces of UHMWPE hydrophobic frit | HF091-25-020 | 100 | IC015B |
|
2.5ml |
Snap Seal |
2.5ml volume, PP two-piece set (snap seal), two pieces of UHMWPE hydrophobic frit | HF091-25-020 | 100 | IC25 |
|
2.5ml |
annular seal |
2.5 ml volume/3 ml inner and outer diameters of column tubing, PP three-piece set (O-ring seal), two pieces of UHMWPE hydrophobic frit | HF090-25-020 | 100 | IC25AA |
|
2.5ml |
Bayonet Seal |
2.5 ml volume/3 ml inner and outer diameters of column tubing, PP two-piece set (bayonet seal), two pieces of UHMWPE hydrophobic frit | HF090-25-020 | 100 | IC25AB |
|
2.5ml |
Bayonet Seal |
2.5 ml volume/6 ml inner and outer diameters of column tubing, PP two-piece set (bayonet seal), two pieces of UHMWPE hydrophobic frit
|
HF130-25-020 | 100 | IC25B |
|
3ml |
annular seal |
3 ml volume/3 ml inner and outer diameters of column tubes, PP three-piece set (O-ring seal), two pieces of UHMWPE hydrophobic frit | HF090-25-020 | 100 | IC3AA |
|
3ml |
Bayonet Seal
|
3 ml volume/3 ml inner and outer diameters of column tubing, PP two-piece set (bayonet seal), two pieces of UHMWPE hydrophobic frit | HF090-25-020 | 100 | IC3AB |
|
6ml |
Bayonet Seal |
6 ml volume/6 ml inner and outer diameters of column tubing, PP two-piece set (bayonet seal), two pieces of UHMWPE hydrophobic frit | HF130-25-020 | 100 | IC6 |
| Customization | Personalized Customization | Customization | Customizing |